4 to 6 °C cooler inside your building.
The PrimaTherm® reflective coating, 95 % solar reflectance and SRI 120 certified, applied to your industrial, logistics and commercial roofs: the roof drops from 60 to 30 °C and the heat stops coming in. No lifting, no shutdown, anywhere in France.
They trust us with their roofs
Roofs transformed, results measured.

Eurotyre — Le Teil: 600 m², −30 °C
60.3 → 29.6 °C measured on the surface.

EGGER Pompes — 400 m²
Steel deck treated in La Verpillière, site in operation.

SET Corp — Saint-Jeoire: 1,500 m²
Reflective membrane under solar panels.

Saint-Laurent-d’Agny school — 600 m²
Cooler classrooms, without air conditioning.
A dark roof absorbs 90 % of the sun. The building pays for the rest.
50 to 70 °C on the surface
Measured on our sites before treatment: here 60 °C on the bare membrane, 25 °C on the treated zone, within the same minute. The heat travels down into the volumes and stresses everything underneath.
- 01
Above 28 °C, productivity drops
Lower output, fatigue, stoppages: summer comfort has become an HR, safety and regulatory issue in workshops and warehouses.
- 02
Air conditioning runs flat out, regulation demands the opposite
Chillers in overdrive, consumption peaks at the most expensive hours, while French tertiary buildings must cut energy use by 40 % by 2030.
- 03
Waterproofing ages prematurely
Repeated thermal shocks, up to 50 to 70 °C at the height of summer, crack membranes and joints. A full re-roofing costs several times the price of a cool roof.
PrimaTherm®: four layers, thirty degrees less.
The PrimaTherm® system is a reflective coating in 4 layers, bonding primer, reflective base in two coats, anti-soiling topcoat, applied directly on your existing roof: steel deck, bitumen membrane or EPDM.
It reflects 95 % of solar radiation and re-emits the absorbed heat (emissivity 0.89). The surface drops from about 60 °C to 30 °C, the cooling load falls, comfort returns, with no structural work, no interruption of activity and no lifting: drums and machines stay on the ground.
- Reflectance 95 % · ASTM E903-12
- Emissivity 0.89 · ASTM C1371-15
- SRI 120 · ASTM E1980
- Fire Broof(t3) · CSTB RA23-0010
- SRI retained · 4,000 h QUV

57.8 °C untreated → 28.6 °C treated
Infrared measurement on the largest building, Marignane, control zone against treated zone, same time of day.

What we measure, you can verify.
Every value comes from a test report (Tipee, CSTB) or from a reception measurement with an infrared thermometer. The reports are attached to our proposals.
Your building, its constraints. Our answer.
A warehouse, a classroom and a meat-processing plant do not overheat the same way and do not qualify for the same incentives.

Industry
Workshops, factories, regulated sites: production and working conditions preserved, with no shutdown.

Logistics
Warehouses and platforms: thousands of square metres of steel deck treated in a few days.

Retail and offices
Air-conditioned sales areas and offices: energy targets and incentives, under conditions.

Public buildings
Schools, sports halls, hospitals: summer comfort without generalised air conditioning.

Food industry and agriculture
Cold chain relieved, heat stress reduced, buildings preserved.

Aerospace and rail
Hangars and maintenance halls on secured sites, under prevention plans.

Four steps, no crane, no interruption of activity.
Drums and machines stay on the ground, only hoses go up to the roof. The site keeps running while we apply.
Free roof study
Satellite measurement, substrate and use analysis, incentive pre-qualification. Reply within 48 h.
Day 2Site visit and proposal
Adhesion tests if needed, system adapted to the substrate, itemised quotation, incentive file.
Day 10Application without lifting
Cleaning, primer, reflective base in two coats, topcoat. Drums on the ground, hoses on the roof, site in operation.
1 week / 3,000 m²Checks and guarantees
Thickness checks, before/after infrared measurements, as-built file, ten-year insurance certificate, maintenance plan.
20-year follow-upWritten commitments, not promises.
Ten-year insurance
Application covered by our professional liability and ten-year insurance. Certificate attached to every proposal.
Certified durability
SRI retained after 4,000 h of accelerated QUV ageing; conventional service life of 20 years.
Incentive file prepared with you
French CEE sheet BAT-EN-112 (air-conditioned commercial buildings, under conditions): eligibility checked, file assembled.
Broof(t3) fire rating
External fire performance validated, CSTB report RA23-0010. Suitable for sensitive sites.
The right questions before you sign.
How much can a cool roof really save?
Up to −40 % of air-conditioning consumption depending on the climate zone, insulation and use of the building, and up to −6 °C felt indoors. We quantify the range in the free study, from your real consumption data, never from a catalogue.
Is my roof compatible with the PrimaTherm® coating?
Steel deck, bitumen membrane and EPDM make up most of our projects. PVC membranes only if laid more than 10 years ago (specific system with a PH107PVC bonding coat). Fibre cement only when asbestos-free. The diagnosis checks the substrate and adhesion before any commitment.
Do I lose heat in winter?
Marginally. The low winter sun mostly hits façades, hardly roofs. The winter loss stays far below the summer gains: the yearly balance is positive everywhere in France, all the more so in the south.
Is a coating really serious compared with re-roofing?
PrimaTherm® is a 4-layer system (PH169 primer, PH107 reflective base in two coats, PH107TCL anti-soiling topcoat), applied according to the manufacturer’s protocol with thickness checks and a site record. It protects the existing waterproofing from thermal shocks; it replaces neither insulation nor waterproofing that has reached the end of its life.
Do you work on sites in operation?
Yes, that is our standard case. Drums and machines stay on the ground, only hoses go up to the roof: no crane, no road closure, no interruption of activity. Our aerospace and rail projects were carried out under prevention plans on secured sites.
Which incentives apply in France?
The French energy-savings certificate scheme (CEE, standard sheet BAT-EN-112) covers air-conditioned commercial buildings under conditions: 160, 170 or 270 kWh cumac per m² depending on the climate zone. Public bodies can use the Fonds Vert. We check your eligibility during the study.
Your free roof study, answered within 48 hours.
Satellite measurement, thermal potential, available incentives: an expert calls you back with facts, never with a catalogue price.