Skip to content
Free roof study — reply within 48 h+33 4 82 53 16 44
Roof of the largest Airbus Marignane building after the PrimaTherm® cool roof application, airport runways in the backgroundRoof of the SNCF Lyon Gerland maintenance centre treated with a cool roof, late afternoonWhite roof of the Airbus Marignane site, runways in the backgroundPVC membrane roof of the Eurotyre centre in Le Teil treated with a cool roofRoof of the Airbus Paris-Le Bourget site treated with a cool roof, equipment kept in placeSET Corp roof in Saint-Jeoire treated with a cool roof under the photovoltaic panelsSteel deck roof of EGGER Pompes in La Verpillière treated with a cool roof
2026 project · Marignane
Cool roof applicator · PrimaTherm®

4 to 6 °C cooler inside your building.

The PrimaTherm® reflective coating, 95 % solar reflectance and SRI 120 certified, applied to your industrial, logistics and commercial roofs: the roof drops from 60 to 30 °C and the heat stops coming in. No lifting, no shutdown, anywhere in France.

Ten-year insuranceSRI 120 certified ASTM E1980Broof(t3) fire ratingReply within 48 h

Your free roof study

Personalised reply within 48 h, no catalogue price.

FreeNo commitmentIncentives checked

Latest large project: 5,900 m² treated, −29 °C measured on the surface.

They trust us with their roofs

  • Logo Airbus
  • Logo SNCF
  • Logo EGGER
  • Logo SET
  • Logo Commune de Saint-Laurent-d’Agny
  • Logo Eurotyre
Every summer, the same story

A dark roof absorbs 90 % of the sun. The building pays for the rest.

Filmed on site · full sun

50 to 70 °C on the surface

Measured on our sites before treatment: here 60 °C on the bare membrane, 25 °C on the treated zone, within the same minute. The heat travels down into the volumes and stresses everything underneath.

Same roof, same minute: 25.4 °C on the treated zone, 60.4 °C on the bare membrane.

  1. 01

    Above 28 °C, productivity drops

    Lower output, fatigue, stoppages: summer comfort has become an HR, safety and regulatory issue in workshops and warehouses.

  2. 02

    Air conditioning runs flat out, regulation demands the opposite

    Chillers in overdrive, consumption peaks at the most expensive hours, while French tertiary buildings must cut energy use by 40 % by 2030.

  3. 03

    Waterproofing ages prematurely

    Repeated thermal shocks, up to 50 to 70 °C at the height of summer, crack membranes and joints. A full re-roofing costs several times the price of a cool roof.

The solution

PrimaTherm®: four layers, thirty degrees less.

The PrimaTherm® system is a reflective coating in 4 layers, bonding primer, reflective base in two coats, anti-soiling topcoat, applied directly on your existing roof: steel deck, bitumen membrane or EPDM.

It reflects 95 % of solar radiation and re-emits the absorbed heat (emissivity 0.89). The surface drops from about 60 °C to 30 °C, the cooling load falls, comfort returns, with no structural work, no interruption of activity and no lifting: drums and machines stay on the ground.

  • Reflectance 95 % · ASTM E903-12
  • Emissivity 0.89 · ASTM C1371-15
  • SRI 120 · ASTM E1980
  • Fire Broof(t3) · CSTB RA23-0010
  • SRI retained · 4,000 h QUV
And in winter? The winter sun is low: it hits façades, hardly roofs. The winter loss is far below the summer savings; the yearly balance stays clearly positive in France.
Roof of the largest building at Airbus Marignane after treatment, full perspective
Reception measurement · 19 June 2026

57.8 °C untreated → 28.6 °C treated

Infrared measurement on the largest building, Marignane, control zone against treated zone, same time of day.

Certified figures, not promises

What we measure, you can verify.

Every value comes from a test report (Tipee, CSTB) or from a reception measurement with an infrared thermometer. The reports are attached to our proposals.

95
of solar radiation reflected
ASTM E903-12
120
SRI, among the highest measured in Europe
ASTM E1980 · Tipee
−29
measured on the surface at the reception of our latest large project
infrared · 19 June 2026
48
to receive a reply to your study request
Hélios commitment
Method

Four steps, no crane, no interruption of activity.

Drums and machines stay on the ground, only hoses go up to the roof. The site keeps running while we apply.

01

Free roof study

Satellite measurement, substrate and use analysis, incentive pre-qualification. Reply within 48 h.

Day 2
02

Site visit and proposal

Adhesion tests if needed, system adapted to the substrate, itemised quotation, incentive file.

Day 10
03

Application without lifting

Cleaning, primer, reflective base in two coats, topcoat. Drums on the ground, hoses on the roof, site in operation.

1 week / 3,000 m²
04

Checks and guarantees

Thickness checks, before/after infrared measurements, as-built file, ten-year insurance certificate, maintenance plan.

20-year follow-up

The application protocol in detail

Guarantees

Written commitments, not promises.

Ten-year insurance

Application covered by our professional liability and ten-year insurance. Certificate attached to every proposal.

Certified durability

SRI retained after 4,000 h of accelerated QUV ageing; conventional service life of 20 years.

Incentive file prepared with you

French CEE sheet BAT-EN-112 (air-conditioned commercial buildings, under conditions): eligibility checked, file assembled.

Broof(t3) fire rating

External fire performance validated, CSTB report RA23-0010. Suitable for sensitive sites.

Frequently asked questions

The right questions before you sign.

How much can a cool roof really save?

Up to −40 % of air-conditioning consumption depending on the climate zone, insulation and use of the building, and up to −6 °C felt indoors. We quantify the range in the free study, from your real consumption data, never from a catalogue.

Is my roof compatible with the PrimaTherm® coating?

Steel deck, bitumen membrane and EPDM make up most of our projects. PVC membranes only if laid more than 10 years ago (specific system with a PH107PVC bonding coat). Fibre cement only when asbestos-free. The diagnosis checks the substrate and adhesion before any commitment.

Do I lose heat in winter?

Marginally. The low winter sun mostly hits façades, hardly roofs. The winter loss stays far below the summer gains: the yearly balance is positive everywhere in France, all the more so in the south.

Is a coating really serious compared with re-roofing?

PrimaTherm® is a 4-layer system (PH169 primer, PH107 reflective base in two coats, PH107TCL anti-soiling topcoat), applied according to the manufacturer’s protocol with thickness checks and a site record. It protects the existing waterproofing from thermal shocks; it replaces neither insulation nor waterproofing that has reached the end of its life.

Do you work on sites in operation?

Yes, that is our standard case. Drums and machines stay on the ground, only hoses go up to the roof: no crane, no road closure, no interruption of activity. Our aerospace and rail projects were carried out under prevention plans on secured sites.

Which incentives apply in France?

The French energy-savings certificate scheme (CEE, standard sheet BAT-EN-112) covers air-conditioned commercial buildings under conditions: 160, 170 or 270 kWh cumac per m² depending on the climate zone. Public bodies can use the Fonds Vert. We check your eligibility during the study.

Let’s talk about your roof

Your free roof study, answered within 48 hours.

Satellite measurement, thermal potential, available incentives: an expert calls you back with facts, never with a catalogue price.